| Sam Beddar, Ph.D., DABR, CRE, FCCPM, FAAPM |
Present Title & Affiliation
Primary Appointment
Professor, Tenured Clinical Faculty Appointment, Department of Radiation Physics - Patient Care, Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX
Service Chief, Gastrointestinal Service, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX
Dual/Joint/Adjunct Appointment
Professeur Adjoint, Département de Physique, Génie Physique et Optique, Université Laval, Québec City, Québec, Canada
Faculty Member, Graduate School of Biomedical Sciences, University of Texas, Houston, TX
Adjunct Professor, Department of Medical Physics, University of Wisconsin School of Medicine & Public Health, Madison, WI
Office Address
The University of Texas MD Anderson Cancer Center
1515 Holcombe Blvd.
Unit Number: 94
Houston, TX 77030
Room Number: Y2.5330
Phone: (713) 563-2609
Fax: (713) 563-2479
Email: abeddar@mdanderson.org
1515 Holcombe Blvd.
Unit Number: 94
Houston, TX 77030
Room Number: Y2.5330
Phone: (713) 563-2609
Fax: (713) 563-2479
Email: abeddar@mdanderson.org
Education & Training
Degree-Granting Education | |
| 1990 | University of Wisconsin, Madison, WI, Ph.D., Medical Physics |
| 1984 | University of Wisconsin, Madison, WI, MS, Medical Physics |
| 1981 | University of Constantine, Constantine, Algeria, MS, Theoretical Physics |
| 1980 | University of Constantine, Constantine, Algeria, BS, Physics |
Board Certifications
| 2012 | Canadian College of Physicists in Medicine |
| 1994 | American Board of Radiology |
Experience/Service
Academic Appointments
Professor, Non-Tenure Clinical Track Appointment, Department of Radiation Physics - Patient Care, Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, 9/2008-8/2011
Associate Professor of Radiation Oncology, Department of Radiation Physics - Patient Care, Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, 5/2002-6/2008
Visiting Professor, Department of Radiation Oncology, Royal Prince Alfred Hospital, Sydney, Australia, 3/2002-5/2002
Assistant Professor, Secondary Appointment, Physics Department, Case Western Reserve University, Cleveland, OH, 8/1999-3/2002
Assistant Professor, Department of Radiation Oncology, University Hospitals of Cleveland, School of Medicine, Case Western Reserve University, Cleveland, OH, 10/1998-3/2002
Assistant Professor, Department of Radiation Oncology, Albany Medical College, Albany, NY, 12/1996-10/1998
Assistant Professor, Department of Radiation Oncology, University of Rochester Medical Center, Rochester, NY, 8/1993-12/1996
Staff Medical Physicist, Department of Clinical Physics, The Ontario Cancer Institute, The Princess Margaret Hospital, Toronto, Canada, 12/1990-8/1993
Institutional Committee Activities
Member, The Center for Radiation Oncology Research Technology Working Group, 1/2013-present
Member, Research Funding Review Panel, Division of Radiation Oncology, 2012-present
Member, Scientific Publications Advisory Board, 2012-present
Senator (elected), Faculty Senate Tenure Issues Committee, 9/2010-8/2012
Chair, Odyssey Program Advisory Committee, 9/2010-9/2011
Co-Chair, Odyssey Program Advisory Committee, 12/2009-8/2010
Senator (elected), Faculty Senate, 9/2009-8/2012
Member, Knudson Award Committee, 2009-2012
Member, Physicist-Scientist Oversight Committee - Department of Radiation Physics - Research, 9/2008-present
Member, Odyssey Program Advisory Committee, 2008-2009
Member, Research Funding Review Panel - Department of Radiation Physics - Research, 9/2007-2011
Member, Research Mentorship Committe, 2007-2011
Member, Continuous Medical Education Advisory Committee (CME), 2006-present
Member, Practitioner Peer Assistance Committee (PPAC), 2005-present
Honors and Awards
| 2013 | PMB EDITOR's CHOICE. The Editor's pick of the best articles recently published in the Journal Physics in Medicine & Bilogy: "On the nature of the light produced within PMMA optical light guides in scintillation fiber-optic dosimetry" François Therriault-Proulx, Luc Beaulieu, Louis Archambault and Sam Beddar 2013 Phys. Med. Biol. 58 2073-2084, Mar 11, 2013., Physics in Medicine and Biology |
| 2012 | Best in Physics (Therapy) Award. Award for the 5 presentations that scored highest in the abstract review process and judged by the Scientific Program Directors to reflect the highest level of scientific quality and innovation, "A Novel multi-point plastic scintillation detector for in vivo dosimetry and quality assurance in radiation therapy", Therriault-Proulx F, Beaulieu L, Archambault L, Beddar S, The American Association of Physicist in Medicine (AAPM Annual Meeting) |
| 2012 | The John R. Cunningham Young Investigators' Competition Symposium, Award for Best Young Investigator Abstract and Presentation. Won the 1st Place Award. "A new optically encoded single-fiber plastic scintillation detector for multi-point radiation dosimetry", Therriault-Proulx F, Beddar S, Archambault L, Beaulieu L, (COMP/CCPM Annual Meeting), 2012, The Canadian Organization of Medical Physicists (COMP) and The Canadian College of Physicists in Medicine (CCPM) |
| 2011 | Award for Best Young Investigator Abstract and Presentation. Won the 2nd place award, "A phantom study demonstrating the efficiency of plastic scintillation detectors for real-time in vivo verification of Ir-192 HDR brachtherapy treatments", Therriault-Proulx F, Beaulieu L, Beddar S, SWAAPM Spring Meeting 2011, The Southwest Chapter of the American Association of Physicists in Medicine (SWAAPM) |
| 2010 | Chairman's Award for Meritorius Services -- Award for outstanding contributions and service to the Department, the Division and the Institution., Department of Radiation Physics, The University of Texas MD Anderson Cancer Center |
| 2010 | Recipient of the 2010 Annual Meeting Basic Science Abstract Award for the abstract titled "Fast and Accurate Verification of Proton Range, Position and Intensity in IMPT with a 3 D Detector System." Archambault L, Poenisch F, Sahoo N, Lee A, Griffin MT, Mohan R, Beddar AS, The American Society of Radiation Oncology (ASTRO) |
| 2010 | The John R. Cunningham Young Investigators' Competition Symposium, Award for Best Young Investigator Abstract and Presentation. Won the 2nd Place Award. "A two dimensional plastic scintillation detector array for quality assurance of intensity modulated radiation therapy". Guillot M*, Gingras L, Archambault L, Beddar S, Beaulieu L. COMP/CCPM Annual Meeting, 2010, The Canadian Organization of Medical Physicists and The Canadian College of Physicists in Medicine |
| 2009 | Award of Excellence for the Best Radiation Measurement Article, The American College of Medical Physics |
| 2009 | Faculty Leadership Academy, The University of Texas M.D. Anderson Cancer Center |
| 2009 | Leadership Award for Special Contributions in Research, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center |
| 2008-present | Fellow of the American Association of Physicists in Medicine, AAPM |
| 2007 | Jack Fowler Junior Investigator Competition Winner, Award for Best Junior Investigator Abstract, "Clinical prototype of a plastic water-equivalent scintillating fiber dosimeter matrix for IMRT QA applications", Lacroix F, Archambault L, Gingras L, Beddar AS, and Beaulieu L. Med Phys 34:2610, 2007, American Association of Physicists in Medicine |
| 2006-2009 | Odyssey Program and Houston Endowment, Inc. Award for Scientific Achievement, "Plastic scintillator dosimeter array for IMRT and IMPT", (Odyssey Fellow: Louis Archambault), The University of Texas MD Anderson Cancer Center |
| 2003 | Citation, "One of the Journals most frequently downloaded articles in 2003" (Beddar AS, Law S, Suchowerska N, and Mackie TR. Plastic scintillation dosimetry: optimization of light collection efficiency. Phys. Med. Biol. 48(9):1141-1152, 2003.) -- 446 downloads --, Physics in Medicine and Biology |
| 1992-present | Fellow of Canadian College of Physicists in Medicine, CCPM |
| 1990 | AAPM Summer School Scholarship, American Association of Physicists in Medicine |
| 1984-1986 | Post-Graduate Scholarship, Le Ministere de l'Enseignement Superieur et de la Recherché Scientifique (M.E.S.R.S.) |
| 1981-1984 | Graduate Scholarship, Le Ministere de l'Enseignement Superieur et de la Recherché Scientifique |
| 1981 | Valedictorian, Institut des Sciences Exactes, Université de Constantine, Algeria, Diploma of Higher Studies |
Professional Memberships
| American Association of Physicists in Medicine (AAPM) Member, 1991-present |
| American College of Medical Physics (ACMP) Full Member, 1998-present |
| American Society for Therapeutic Radiology and Oncology (ASTRO) Associate Member, 2006-present |
| Canadian College of Physicists in Medicine (CCPM) Full Member, 1990-present |
| Canadian Organization of Medical Physicists (COMP) Full Member, 1990-present |
| European Society for Therapeutic Radiology and Oncology (ESTRO) Full Member, 1995-present |
| International Society of IntraOperative Radiation Therapy (ISIORT) Member, Quality Assurance Program for Clinical Trials, 2000-present |
Selected Publications
Peer-Reviewed Original Research Articles | ||
| 1. | Beaulieu L, Goulet M, Archambault L and Beddar S. Current status of Scintillation Dosimetry for megavoltage beans. J. Phys. Conf. Ser. In Press. | |
| 2. | Das P, Abboud MT, Haque W, Javle M, Kaseb A, Curley SA, Vauthey JN, Aloia TA, Beddar S, Delclos ME, Krishnan S, Crane CH. Gastric bleeding after radiation therapy for intrahepatic cholangiocarcinoma. Practical Radiation Oncology. In Press. | |
| 3. | Guillot M, Gingras L, Archambault L, Beddar S, Beaulieu L. Performance assessment of a 2D array of plastic scintillation detectors for IMRT quality assurance. Phys Med Biol. In Press. | |
| 4. | Therriault-Proulx F, Beaulieu L, Archambault L, Beddar S. On the nature of the light produced within PMMA optical light guides in scintillation fiber-optic dosimetry. Phys Med Biol 58(7):2073-2084, 4/7/2013. e-Pub 3/8/2013. PMID: 23470253. | |
| 5. | Wootton L, Beddar S. Temperature dependence of BCF plastic scintillation detectors. Phys Med Biol 58(9). e-Pub 4/11/2013. PMID: 23574889. | |
| 6. | Kelly P, Das P, Pinnix CC, Beddar S, Briere T, Pham M, Krishnan S, Delclos ME, Crane CH. Duodenal Toxicity after fractionated chemoradiation for unresectable pancreatic cancer. Int J Radiat Oncol Biol Phys 85(3):e143-9, 3/1/2013. e-Pub 11/29/2012. PMID: 23200173. | |
| 7. | Mitchell MP, Abboud M, Eng C, Beddar AS, Krishnan S, Delclos ME, Crane CH, Das P. Intensity-modulated radiation therapy with concurrent chemotherapy for anal cancer: Outcomes and toxicity. Am J Clin Oncol. e-Pub 3/4/2013. PMID: 23466576. | |
| 8. | Robertson D, Mirkovic D, Sahoo N, Beddar S. Quenching correction for volumetric scintillation dosimetry of proton beams. Phys Med Biol 58(2):261-273, 1/21/2013. e-Pub 12/21/2012. PMID: 23257200. | |
| 9. | Morin J, Beliveau-Nadeau D, Chung E, Seuntjens J, Theriault D, Archambault L, Beddar S, Beaulieu L. A comparative study of small field total scatter factors and dose profiles using plastic scintillation detectors and other stereotactic dosimeters: the case of the Cyberknife. Med Phys 40(1):011719, (11 pages), 1/2013. PMID: 23298089. | |
| 10. | Mackin D, Polf J, Peterson S, Beddar S. The effects of Doppler broadening and detector resolution on the performance of three-stage Compton cameras. Med Phys 40(1):012402, (12 pages), 1/2013. PMCID: PMC3537711. | |
| 11. | Wang LL, Perles LA, Archambault L, Sahoo N, Mirkovic D, Beddar S. Determination of the quenching correction factors for plastic scintillation detectors in therapeutic high-energy proton beams. Phys Med Biol 57(23):7767-7781, 11/2012. PMID: 23128412. | |
| 12. | Klein D, Briere TM, Kudchadker R, Archambault L, Beaulieu L, Lee A, Beddar S. In-phantom dose verification of prostate IMRT and VMAT deliveries using plastic scintillation detectors. Radiat Meas 47(10):921-929, 10/1/2012. e-Pub 8/24/2012. PMCID: PMC3501761. | |
| 13. | Archambault L, Therriault-Proulx F, Beddar S, Beaulieu L. A mathematical formalism for hyperspectral, multipoint plastic scintillation detectors. Phys Med Biol 57(21):7133-7145, 10/2012. PMID: 23060036. | |
| 14. | Therriault-Proulx F, Archambault L, Beaulieu L, Beddar S. Development of a novel multi-point plastic scintillation detector with a single optical transmission line for radiation dose measurement. Phys Med Biol 57(21):7147-7159, 10/2012. PMID: 23060069. | |
| 15. | Beddar S. On possible temperature dependence of plastic scintillator response. Med Phys 39(10):6522, 10/2012. PMID: 23039686. | |
| 16. | Lessard F, Archambault L, Plamondon M, Després P, Therriault-Proulx F, Beddar S, Beaulieu L. Validating plastic scintillation detectors for photon dosimetry in the radiologic energy range. Med Phys 39(9):5308-5316, 9/2012. PMID: 22957599. | |
| 17. | Briere TM, Crane CH, Beddar S, Bhosale P, Mok H, Delclos ME, Krishnan S, Das P. Reproducibility and genital sparing with a vaginal dilator used for female anal cancer patients. Radiother Oncol 104(2):161-166, 8/2012. e-Pub 7/26/2012. PMID: 22841019. | |
| 18. | Archambault L, Beaulieu L, Beddar S. Comment on 'Plastic scintillation dosimetry: comparison of three solutions for the Cerenkov challenge'. Phys Med Biol 57(11):3661-3665; discussion 3667-73, 6/2012. PMID: 22596092. | |
| 19. | Mackin D, Peterson S, Beddar S, Polf J. Evaluation of a stochastic reconstruction algorithm for use in Compton camera imaging and beam range verification from secondary gamma emission during proton therapy. Phys Med Biol 57(11):3537-3553, 6/2012. PMID: 22588144. | |
| 20. | Chakravarty T, Crane CH, Ajani JA, Mansfield PF, Briere TM, Beddar AS, Mok H, Reed VK, Krishnan S, Delclos ME, Das P. Intensity modulated radiation therapy with concurrent chemotherapy as preoperative treatment for localized gastric adenocarcinoma. Int J Radiat Oncol Biol Phys 83(2):581-586, 6/2012. PMID: 22137021. | |
| 21. | Wootton LS, Polf JC, Peterson S, Wilkinson J, Rozner MA, Balter PA, Beddar S. Proton dose perturbations caused by high-voltage leads from implanted cardioverter defibrillators. J Appl Clin Med Phys 13(4):13-22, 5/2012. PMID: 22766952. | |
| 22. | Archambault L, Poenisch F, Sahoo N, Robertson D, Lee A, Gillin MT, Mohan R, Beddar S. Verification of proton range, position, and intensity in IMPT with a 3D liquid scintillator detector system. Med Phys 39(3):1239-1246, 3/2012. PMCID: PMC3292596. | |
| 23. | Gagnon JC, Thérriault D, Guillot M, Archambault L, Beddar S, Gingras L, Beaulieu L. Dosimetric performance and array assessment of plastic scintillation detectors for stereotactic radiosurgery quality assurance. Med Phys 39(1):429-436, 1/2012. PMID: 22225313. | |
| 24. | Wootton LS, Kudchadker RJ, Beddar AS, Lee AK. Effectiveness of a novel gas-release endorectal balloon in the removal of rectal gas for prostate proton radiation therapy. J Appl Clin Med Phys 13(5):190-197, 2012. e-Pub 9/6/2012. PMID: 22955660. | |
| 25. | Guillot M, Beaulieu L, Archambault L, Beddar S, Gingras L. A new water-equivalent 2D plastic scintillation detectors array for the dosimetry of megavoltage energy photon beams in radiation therapy. Med Phys 38(12):6763-74, 12/2011. PMID: 22149858. | |
| 26. | Mok H, Crane CH, Palmer MB, Briere TM, Beddar S, Delclos ME, Krishnan S, Das P. Intensity modulated radiation therapy (IMRT): differences in target volumes and improvement in clinically relevant doses to small bowel in rectal carcinoma. Radiat Oncol 6(63):2-9, 6/2011. PMCID: PMC3121606. | |
| 27. | Therriault-Proulx F, Briere TM, Mourtada F, Aubin S, Beddar S, Beaulieu L. A phantom study of an in vivo dosimetry system using plastic scintillation detectors for real-time verification of 192Ir HDR brachytherapy. Med Phys 38(5):2542-51, 5/2011. PMCID: PMC3104721. | |
| 28. | Tremblay NM, Hubert-Tremblay V, Bujold R, Beddar AS, Beaulieu L, Lepage M. Accurate calibration of a polymer gel dosimeter with a plastic scintillation detector. Med Phys 38(5):2754-2761, 5/2011. PMID: 21776812. | |
| 29. | Robertson D, Polf JC, Peterson SW, Gillin MT, Beddar S. Material efficiency studies for a Compton camera designed to measure characteristic prompt gamma rays emitted during proton beam radiotherapy. Phys Med Biol 56(10):3047-3059, 5/2011. PMCID: PMC3087185. | |
| 30. | Therriault-Proulx F, Beddar S, Briere TM, Archambault L, Beaulieu L. Removing the stem effect when performing Ir-192 HDR brachytherapy in vivo dosimetry using plastic scintillation detectors: a relevant and necessary step. Med Phys 38(4):2176-9, 4/2011. PMCID: PMC3188655. | |
| 31. | Guillot M, Gingras L, Archambault L, Beddar S, Beaulieu L. Spectral method for the correction of the Cerenkov light effect in plastic scintillation detectors: a comparison study of calibration procedures and validation in Cerenkov light-dominated situations. Med Phys 38(4):2140-50, 4/2011. PMCID: PMC3078161. | |
| 32. | Klein DM, Therriault-Proulx F, Archambault L, Briere TM, Beaulieu L, Beddar AS. Determining regions of interest for CCD camera-based fiber optic luminescence dosimetry by examining signal-to-noise ratio. Med Phys 38(3):1374-7, 3/2011. PMCID: PMC3055908. | |
| 33. | Wang LL, Beddar S. Study of the response of plastic scintillation detectors in small-field 6 MV photon beams by Monte Carlo simulations. Med Phys 38(4):1596-1599, 3/2011. PMCID: PMC3064682. | |
| 34. | Mok H, Briere TM, Martel MK, Beddar AS, Delclos ME, Krishnan S, Crane CH, Das P. Comparative analysis of volumetric modulated arc therapy (VMAT) versus intensity modulated radiation therapy (IMRT) for radiotherapy of anal carcinoma. Practical Radiation Oncology(1):163-172, 1/2011. | |
| 35. | Polf JC, Peterson S, Robertson D, Beddar S. Measuring prompt gamma ray emission during proton radiotherapy for assessment of treatment delivery and patient response. AIP Conference Proceedings 1336:364-368, 2011. | |
| 36. | Klein DM, Tailor RC, Archambault L, Wang L, Therriault-Proulx F, Beddar AS. Measuring output factors of small fields formed by collimator jaws and multileaf collimators using plastic scintillation detectors. Med Phys 37(10):5541-5549, 10/2010. PMCID: PMC2962666. | |
| 37. | Wang LL, Klein D, Beddar AS. Monte Carlo study of the energy and angular dependence of the response of plastic scintillation detectors in photon beams. Med Phys 37(10):5279-86, 10/2010. PMCID: PMC2951997. | |
| 38. | Archambault L, Briere TM, Poénisch F, Beaulieu L, Kuban DA, Lee A, Beddar S. Toward a real-time in vivo dosimetry system using plastic scintillation detectors. Int J Radiat Oncol Biol Phys 78(1):280-287, 9/2010. PMCID: PMC2889037. | |
| 39. | Lacroix F, Guillot M, McEwen M, Cojocaru C, Gingras L, Beddar AS, Beaulieu L. Extraction of depth-dependent perturbation factors for parallel-plate chambers in elecron beams using plastic scintillation detector. Med Phys 37(8):4331-4342, 8/2010. PMCID: PMC2927689. | |
| 40. | Lacroix F, Beaulieu L, Archambault L, Beddar AS. Simulation of the precision limits of plastic scintillation detectors using optimal component selection. Med Phys 37(2):412-418, 2/2010. PMCID: PMC2814832. | |
| 41. | Beddar S. A liquid scintillator system for dosimetry of photon and proton beams. J. Phys. Conf. Ser. 250 (012038):1-3, 2010. | |
| 42. | Guillot M, Gingras L, Archambault L, Beddar S, Beaulieu L. Toward 3D dosimetry of intensity modulated radiation therapy treatments with plastic scintillation detectors. J. Phys. Conf. Ser. 250 (012006):1-5, 2010. | |
| 43. | Lacroix F, Beddar AS, Guillot M, Beaulieu L and Gingras L. A design methodology using signal-to-noise ratio for plastic scintillation detectors design and performance optimization. Med Phys 36(11):5214-5220, 11/2009. PMCID: PMC2774352. | |
| 44. | Polf JC, Peterson S, McCleskey M, Roeder BT, Spiridon A, Beddar AS, Trache L.. Measurement and calculation of characteristic prompt gamma ray spectra emitted during proton irradiation. Phys Med Biol 54(22):N519-N527, 11/2009. PMID: 19864704. | |
| 45. | Bouchard M, Amos RA, Briere TM, Beddar AS, and Crane CH. Dose escalation with proton or photon radiation treatment for pancreatic cancer. Radiother Oncol 92(2):238-243, 8/2009. PMID: 19454367. | |
| 46. | Peterson SW, Polf J, Bues M, Ciangaru G, Archambault L, Beddar AS, Smith A. Experimental validation of a Monte Carlo proton therapy nozzle model incorporating magnetically steered protons. Phys Med Biol 54(10):3217-29, 2009. PMID: 19420426. | |
| 47. | Beddar AS, Archambault L, Sahoo N, Poenisch F, Chen GT, Gillin MT, and Mohan R. Exploration of the potential of liquid scintillators for real-time 3D dosimetry of intensity modulated proton beams. Med Phys 36(5):1736-1743, 2009. PMID: 19544791. | |
| 48. | Hodges JC, Das P, Eng C, Reish AG, Beddar AS, Delclos ME, Krishnan S, and Crane CH. Intensity-modulated radiation therapy for the treatment of squamous cell anal cancer with para-aortic nodal involvement. Int J Radiat Oncol Biol Phys 75(3):791-794, 2009. PMID: 19231109. | |
| 49. | Poenisch F, Archambault L, Briere TM, Sahoo N, Mohan R, Beddar AS, and Gillin MT. Liquid scintillator for 2D dosimetry for high-energy photon beams. Med Phys 36(5):1478-1485, 2009. PMID: 19544763. | |
| 50. | Polf JC, Peterson S, Ciangaru G, Gillin M and Beddar AS. Prompt gamma-ray emission from biological tissues during proton irradiation: A preliminary study. Phys Med Biol 54(3):731-743, 2009. PMID: 19131673. | |
| 51. | Briere TM, Beddar AS, Balter P, Murthy R, Gupta S, Nelson C, Starkschall G, Gillin MT, and Krishnan S. Respiratory gating with EPID-based verification: The University of Texas MD Anderson Cancer Center experience. Phys Med Biol 54(11):3379-91, 2009. PMID: 19436104. | |
| 52. | Beddar AS, Briere TM, Balter P, Pan T, Tolani N, Ng C, Szklaruk J, and Krishnan S. 4D-CT imaging with synchronized intravenous contrast injection to improve delineation of liver tumors for treatment planning. Radiother Oncol 87(3):445-448, 2008. PMID: 18194819. | |
| 53. | Archambault L, Polf JC, Beaulieu L, and Beddar AS. Characterizing the response of miniature scintillation detectors when irradiated with proton beams. Phys Med Biol 53(7):1865-1876, 2008. PMID: 18364543. | |
| 54. | Lacroix F, Archambault L, Gingras L, Guillot M, Beddar AS, and Beaulieu L. Clinical prototype of a plastic water-equivalent scintillating fiber dosimeter array for QA applications. Med Phys 35(8):3682-3690, 2008. PMID: 18777928. | |
| 55. | Wang H, Krishnan S, Wang X, Beddar AS, Briere TM, Crane CH, Mohan R, Dong L. Improving soft-tissue contrast in four-dimensional computed tomography images of liver cancer patients using a deformable image registration method. Int J Radiat Oncol Biol Phys 72(1):201-9, 2008. PMID: 18722271. | |
| 56. | Briere TM, Tailor R, Tolani N, Prado K, Lane R, Woo S, Ha C, Gillin MT, Beddar AS. Patient dosimetry for total body irradiation using single-use MOSFET detectors. J Appl Clin Med Phys 9(4):2787, 2008. PMID: 19020482. | |
| 57. | Wang X, Krishnan S, Dong L, Briere TM, Crane CH, Gillin MT, Mohan R, and Beddar AS. Proton radiotherapy for liver tumors: Dosimetric advantages over photon plans. Med Dosim 33(4):259-267, 2008. PMID: 18973852. | |
| 58. | Krishnan K, Dawson LA, Seong J, Akine Y, Beddar AS, Briere TM, Crane CH, and Mornex F. Radiotherapy for hepatocellular carcinoma: An overview. Ann Surg Oncol 15(4):1015-1024, 2008. PMID: 18236114. | |
| 59. | Archambault L, Briere TM, and Beddar AS. Transient noise characterization and filtration in CCD cameras exposed to stray radiation from a medical linear accelerator. Med Phys 35(10):4342-4351, 2008. PMID: 18975680. | |
| 60. | Beddar AS, Kainz K, Briere TM, Tsunashima Y, Pan T, Prado K, Mohan R, Gillin M, and Krishnan S. Correlation between internal fiducial tumor motion and external marker motion for liver tumors imaged with 4D-CT. Int J Radiat Oncol Biol Phys 67(2):630-638, 2007. PMID: 17236980. | |
| 61. | Krishnan S, Briere TM, Dong L, Murthy R, Ng C, Balter P, Mohan R, Gillin MT, and Beddar AS. Daily targeting of liver tumors: Screening patients with a mock treatment and using a combination of internal and external fiducials for image-guided respiratory-gated radiotherapy. Med Phys 34(12):4591-4593, 2007. PMID: 18196785. | |
| 62. | Vedam S, Archambault L, Starkschall G, Mohan R, and Beddar AS. Determination of prospective displacement-based gate threshold for respiratory-gated radiation delivery from retrospective phase-based gate threshold selected at 4D CT simulation. Med Phys 34(11):4247-4255, 2007. PMID: 18072489. | |
| 63. | Gao S, Delclos ME, Tomas LC, Crane CH, and Beddar AS. High dose rate remote afterloaders for intraoperative radiation therapy. AORN J 86(5):827-836, 2007. PMID: 18050890. | |
| 64. | Briere TM, Gillin MT, and Beddar AS. Implantable MOSFET detectors: Evaluation of a new design. Med Phys 34(12):4585-4590, 2007. PMID: 18196784. | |
| 65. | Beddar AS. Plastic scintillation dosimetry and its application to radiotherapy. Invited. Radiat Meas 41(S124-S133), 2007. | |
| 66. | Ballo MT, Zagars GK, Pollock RE, Benjamin RS, Feig BW, Cormier JN, Hunt KK, Patel SR, Trent JC, Beddar S, and Pisters PW. Retroperitoneal soft tissue sarcoma: An analysis of radiation and surgical treatment. Int J Radiat Oncol Biol Phys 67(1):158-163, 2007. PMID: 17084545. | |
| 67. | Archambault L, Beddar AS, Gingras L, Roy R, and Beaulieu L. Water-equivalent dosimeter array for small field external beam radiotherapy. Med Phys 34(5):1583-1592, 2007. PMID: 17555240. | |
| 68. | Krishnan S, Lin EH, Gunn GB, Chandra A, Beddar AS, Briere TM, Das P, Delclos ME, Janjan NA, and Crane CH. Conformal radiotherapy of the dominant liver metastasis: A viable strategy for treatment of unresectable chemotherapy refractory colorectal cancer liver metastases. Am J Clin Oncol 29(6):562-567, 2006. PMID: 17148992. | |
| 69. | Beddar AS, Briere TM, and Ouzidane M. Intraoperative radiation therapy using a mobile electron linear accelerator: Field matching for large-field electron irradiation. Phys Med Biol 51(18):N331-337, 2006. PMID: 16953035. | |
| 70. | Beddar AS, Biggs PJ, Chang S, Ezzell GA, Faddegon BA, Hensley FW, and Mills MD. Intraoperative radiation therapy using mobile electron linear accelerators: Report of AAPM Radiation Therapy Committee Task Group No. 72. Med Phys 33:1476-1489, 2006. PMID: 16752582. | |
| 71. | Archambault L, Beddar AS, Gingras L, Roy R, and Beaulieu L. Measurement accuracy and cerenkov removal for high performance, high spatial resolution scintillation dosimetry. Med Phys 33:128-135, 2006. PMID: 16485419. | |
| 72. | Briere TM, Lii J, Prado K, Gilin MT, and Beddar AS. Single-use MOSFET radiation dosimeters for the quality assurance of megavoltage photon beams. Phys Med Biol 51(5):1139-1144, 2006. PMID: 16481683. | |
| 73. | Ayotte G, Archambault L, Gingras L, Lacroix F, Beddar AS, Beaulieu L. Surface preparation and coupling in plastic scintillator dosimetry. Med Phys 33(9):3519-3525, 2006. PMID: 17022248. | |
| 74. | Beddar AS, Krishnan S, Briere TM, Wang X, Delclos ME, Ballo MT, Das P, Gould S, Horton JL, and Crane CH. The optimization of dose delivery for intraoperative high-dose-rate radiation therapy using curved HAM applicators. Radiother Oncol 78:207-212, 2006. PMID: 16376445. | |
| 75. | Beddas AS. Water equivalent plastic scintillation detectors in radiation therapy. Invited. Radiat Prot Dosimetry 120:1-6, 2006. | |
| 76. | Briere TM, Beddar AS, and Gillin MT. Evaluation of precalibrated implantable MOSFET radiation dosimeters for megavoltage photon beams. Med Phys 32:3346-3349, 2005. PMID: 16370421. | |
| 77. | Beddar AS and Krishnan S. Intraoperative radiotherapy using a mobile electron LINAC: A retroperitoneal sarcoma case. J Appl Clin Med Phys 6:95-107, 2005. PMID: 16143794. | |
| 78. | Beddar AS, Briere TM, Mourtada FA, Vassiliev ON, Liu HH, and Mohan R. Monte Carlo calculations of the absorbed dose and energy dependence of plastic scintillators. Med Phys 32:1265-1269, 2005. PMID: 15984678. | |
| 79. | Archambault L, Arsenault J, Gingras L, Beddar AS, Roy R, and Beaulieu L. Plastic scintillation dosimetry: optimal selection of scintillating fibers and scintillators. Med Phys 32:2271-2278, 2005. PMID: 16121582. | |
| 80. | Beddar AS, Salehpour M, Briere TM, Hamidian H, and Gillin MT. Preliminary evaluation of implantable MOSFET radiation dosimeters. Phys Med Biol 50:141-149, 2005. PMID: 15715428. | |
| 81. | Beddar AS. Stability of a mobile electron linear accelerator system for intraoperative radiation therapy. Med Phys 32:3128-3131, 2005. PMID: 16279065. | |
| 82. | Zhang P, Beddar AS, and Sibata CH. AAPM TG-43 formalism for brachytherapy dose calculation of a 137Cs tube source. Med Phys 31:755-759, 2004. PMID: 15124992. | |
| 83. | Beddar AS and Tailor RC. Calibration of low-energy electron beams from a mobile linear accelerator with plane-parallel chambers using both TG-51 and TG-21 protocols. Phys Med Biol 49:N105-N110, 2004. PMID: 15152696. | |
| 84. | Beddar AS, Suchowerska N, and Law SH. Plastic scintillation dosimetry for radiation therapy: Minimizing capture of Cerenkov radiation noise. Phys Med Biol 49:783-790, 2004. PMID: 15070202. | |
| 85. | Ellis RJ, Vertocnik A, Kim E, Zhou H, Young B, Sodee B, Fu P, Beddar AS, Colussi V, Spirnak JP, Dinchman KH, Resnick M, and Kinsella TJ. Four-year biochemical outcome after radioimmunoguided transperineal brachytherapy for patients with prostate adenocarcinoma. Int J Radiat Oncol Biol Phys 57(2):362-370, 2003. PMID: 12957246. | |
| 86. | Beddar AS, Law S, Suchowerska N, and Mackie TR. Plastic scintillation dosimetry: Optimization of light collection efficiency. Phys Med Biol 48:1141-52, 2003. | |
| 87. | Crane CH, Beddar AS, Evans DB. The role of intraoperative radiotherapy in pancreatic cancer. Surg Oncol Clin N Am 12(4):965-77, 2003. PMID: 14989127. | |
| 88. | Beddar AS, Kinsella TJ, Ikhlef A, and Sibata CH. A miniature scintillator-fiberoptic-PMT detector system for the dosimetry of small fields in stereotactic radiosurgery. IEEE Trans Nucl Sci 48:924-928, 2001. | |
| 89. | Beddar AS, Kubo ML, Domanovic MA, Ellis RJ, Kinsella TJ, and Sibata CH. A new approach to intraoperative radiation therapy. AORN J 74(4):500-505, 2001. PMID: 11665383. | |
| 90. | Colussi VC, Beddar AS, Kinsella TJ, Sibata CH. In vivo dosimetry using a single diode for megavoltage photon beam radiotherapy: implementation and response characterization. J Appl Clin Med Phys 2(4):210-8, 2001. PMID: 11686742. | |
| 91. | Beddar AS, Domanovic MA, Kubo ML, Ellis RJ, Sibata CH, and Kinsella TJ. Mobile linear accelerators for intraoperative radiation therapy. AORN Journal 74(5):700-705, 2001. PMID: 11725448. | |
| 92. | Ellis RJ, Kim EY, Conant R, Sodee DB, Spirnak JP, Dinchman KH, Beddar AS, Wessels B, Resnick MI, and Kinsella TJ. Radioimmunoguided imaging of prostate cancer foci with histopathological correlation. Int J Radiat Oncol Biol Phys 49(5):1281-1286, 2001. PMID: 11286835. | |
| 93. | Ikhlef A, Skowronek M, and Beddar AS. X-ray imaging and detection using plastic scintillating fibers. Nuclear Instruments and Methods in Physics Research A 442:428-432, 2000. | |
| 94. | Das IJ, Gazda MJ, and Beddar AS. Characteristics of a scintillator-based daily quality assurance device for radiation oncology beams. Med Phys 23(12):2061-2067, 1996. PMID: 8994171. | |
| 95. | Beddar AS. A new scintillator detector system for the quality assurance of Co-60 and high-energy therapy machines. Phys Med Biol 39(2):253-263, 1994. PMID: 15552123. | |
| 96. | Beddar AS, Mason DJ, O'Brien PF. Absorbed dose perturbation caused by diodes for small field photon dosimetry. Med Phys 21(7):1075-9, 1994. PMID: 7968839. | |
| 97. | Beddar AS, Thomason C, and Leung PMK. Description and evaluation of a new 3D computerized treatment planning dose compensator system. Med Dosim 19(4):227-235, 1994. PMID: 7893357. | |
| 98. | de Boer SF, Beddar AS, and Rawlinson JA. Optical filtering and spectral measurements of radiation-induced light in plastic scintillation dosimetry. Phys Med Biol 38:945-958, 1993. | |
| 99. | Beddar AS, Mackie TR, and Attix FH. Cerenkov light generated in optical fibers and other light-pipes irradiated by electron beams. Phys Med Biol 37:925-935, 1992. | |
| 100. | Beddar AS, Mackie TR, Attix FH. Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical consideration. Phys Med Biol 37(10):1883-900, 1992. PMID: 1438554. | |
| 101. | Beddar AS, Mackie TR, Attix FH. Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurements. Phys Med Biol 37(10):1901-13, 1992. PMID: 1438555. | |
| 102. | Sibata CH, Mota HC, Beddar AS, Higgins PD, and Shin KH. Influence of detector size in photon beam profile measurements. Phys Med Biol 36(5):621-631, 1991. PMID: 2068227. | |
| 103. | Beddar AS and Higgins PD. Use of ferroelectric crystal detectors for electron dosimetry. IEEE Trans Ultrason Ferroelectr Freq Control 37(1):26-30, 1990. PMID: 18285012. | |
| 104. | Beddar AS and Higgins PD. Ionizing radiation response effects on optical fibers in radiation therapy dosimetry applications. SPIE 992:170-176, 1988. | |
Invited Articles | ||
| 1. | Tanderup K, Beddar S, Andersen CE, Kertzscher G and Joanna E Cygler J. Vision 20/20 Article: In vivo dosimetry brachytherapy. Med Phys. In Press. | |
| 2. | Mijnheer B, Beddar S, Izewska J and Reft Chester. Vision 20/20 Article: In vivo dosimetry in external beam radiotherapy. Med Phys. In Press. | |
| 3. | Beddar AS. Plastic scintillation dosimetry and its application to radiotherapy. Radiat Meas 41:S124-S133, 2007. | |
| 4. | Beddar AS. Water equivalent plastic scintillation detectors in radiation therapy. Radiat Prot Dosimetry 120(1-4):1-6, 2006. e-Pub 8/1/2006. PMID: 16882685. | |
| 5. | Law SH, Suchowerska N, Fleming SC, Beddar AS, and McKenzie D. Signal versus noise in fiber coupled radiation dosimeters for medical applications. Biomedical Optics, Proceedings of SPIE. Biomedical Optics, SPIE 5317:105-115, 2004. | |
| 6. | Domanovik MA, Ouzidane M, Ellis RJ, Kinsella TJ, and Beddar AS. Using intraoperative radiation therapy - A case study. AORN J 77(2):412-417, 2003. PMID: 12619854. | |
| 7. | Beddar AS. Radiation response of optical fibers to clinical radiotherapy photon and electron beams. Opto-Electronics: ESI publications; Paris, 146-149, 1988. | |
| Other Articles | ||
| 1. | Beddar AS, Archambault, L, Briere TM, Lacroix F, Gingras L, and Beaulieu L. Recent developments in scintillating fiber detection systems in radiation therapy. Proceedings of the SPIE 6913:69130R(1-9), 2008. | |
| 2. | Law S and Beddar AS. Capture of Cerenkov radiation generated on the axis of an optical fibre when the fibre axis lies on the Cerenkov cone. Conference on the Optical Internet/Australian Conference on Optical Fibre Technology 2003, Melbourne, Australia. EA Books, 2003. | |
| 3. | Kirov AS, Piao, Z, Devic, S, Shrinivas S, Beddar AS, Binns WR, Kinsella TJ, and Sibata CH. An estimate of the perturbing effect of Cerenkov radiation to the signal from a liquid scintillator volume irradiated by a megavoltage photon beam. Proceedings of the 22nd Annual EMBS International Conference, 2000, Chicago, IL,. IEEE 4:3148-3151, 2000. | |
Abstracts | ||
| 1. | Mitchell MP, Abboud M, Crane CH, Eng GJ, Chang MA Rodriguez-Bigas JM, Skibber YN, You S, Beddar S, Krishnan ME, Delclos P, Das S. Intensity modulated radiation therapy (IMRT) with concurrent chemotherapy for anal cancer: A lage single institution experience. 2011 Gastrointestinal Cancers Symposium, 1/2011. | |
| 2. | Wang L, Perles L Archambault L, Sahoo N, Beddar, Mirkovic D. Application of a plastic scintillation detector in measuring depth-dose curves for passive-scattering proton beams. AAPM/COMP Meeting, Vancouver, BC, Med. Phys. 38(6):3366, 6/2011. | |
| 3. | Mackin D, Polf J, Peterson S, Gillin M, Beddar S. Evaluating a stochastic reconstruction algorithm for compton camera based prompt gamma imaging during proton therapy. AAPM/COMP Meeting, Vancouver, BC, Med Phys 38(6):3567-3568, 6/2011. | |
| 4. | Klein D, Wootton L, Tailor R, Beddar S. Investigating the effects of using several calibration conditions on the measurement accuracy of plastic scintillation detectors. AAPM/COMP Meeting, Vancouver, BC, Med Phys 38(6):3367, 6/2011. | |
| 5. | Paganetti H, Jeraj R, Beddar S. Practical research advice: NIH navigation and grantsmanship. AAPM/COMP Meeting, Vancouver, BC, Med Phys 38(6):3738, 6/2011. | |
| 6. | Peterson S, Polf J, Mackin D, Beddar S, Gillin M. Reconstructing images of prompt gammas emitted during proton radiotherapy. AAPM/COMP Meeting, Vancouver, BC, Med Phys 38(6):3853, 6/2011. | |
| 7. | Robertson D, Mirkovic D, Mohan R, Beddar S. Voxelized quenching correction for proton pencil beams in a liquid scintillator detector. AAPM/COMP Meeting, Vancouver, BC, Med Phys 38(6):3816, 6/2011. | |
| 8. | Abboud M T, Crane C, Javie M, Kaseb A, Haque W, Delclos M, Krishnan S, Beddar S, Briere T, Das P. Risk factors for gastrointestinal bleeding in patients treated with radiation therapy for intrahepatic cholangiocarcinoma. ASTRO Annual Meeting, Miami Beach, FL, Int J Radia Oncol Biol Phys 81(2):S354, 10/2011. | |
| 9. | Kelley P, Das, P, Pinnix C, Beddar S, Pham M, Krishnan S, Delclos ME, Crane CH. Duodenal toxicity after fractionated chemoradiation for unresectable pancreatic cancer. ASTRO Annual Meeting, Miami Beach, FL, Int J Radia Oncol Biol Phys 81(2):S70, 2011. | |
| 10. | Therriault-Proulx, Archambault L, Beddar S, Beaulieu L. A revolutionary multi-point plastic scintillation detector for in-vivo dosimetry in HDR brachytheray. ESTRO 31 Conference, Barcelona, Spain. Radiother Oncol 103(S2):S28, 5/2012. | |
| 11. | Morin J, Béliveau-Nadeau D, Chung E, Seuntjens J, Archambault L, Beddar S, Beaulieu L. A sub-millimeter plastic scintillation detector for small field measurements delivered by a CyberKnife unit. ESTRO 31 Conference, Barcelona, Spain. Radiother Oncol 103(S1):S207-S208, 5/2012. | |
| 12. | Bourgouin A, Bonde C, Adams E, Schmidt D, Beddar S, Beaulieu L, Archambault L. Characterization and validation of a commercial plastic scintillation detector prototype. ESTRO 31 Conference, Barcelona, Spain. Radiother Oncol 103(S1):S315, 5/2012. | |
| 13. | Beddar S, Robertson D, Archambault L, Mohan R. Correction of optical artifacts in a liquid scintillator dosimetry system. ESTRO 31 Conference, Barcelona, Spain. Radiother Oncol 103(S1):S22, 5/2012. | |
| 14. | Therriault-Proulx F, Archambault L, Beaulieu L, Beddar S. Development and application of a novel multi-point plastic scintillation detector for radiation therapy. ESTRO 31 Conference, Barcelona, Spain. Radiother Oncol 103(S1):S85-S86, 5/2012. | |
| 15. | Archambault L, Therriault-Proulx F, Beddar S, Beaulieu L. Formalism for hyper-spectral, multi-point, plastic scintillation detectors. ESTRO 31 Conference, Barcelona, Spain. Radiother Oncol 103(S1):S313-S314, 5/2012. | |
| 16. | Beddar S. Implantable MOSFET dosimeters. ESTRO 31 Conference, Barcelona, Spain. Radiother Oncol 103(S1):S76-S77, 5/2012. | |
| 17. | Klein DM, Wootton LS, Kudchadker RJ, Lee AK, Beddar AS. In-phantom dose verification of four-field box and IMRT treatment delivery using plastic scintillation detectors. ESTRO 31 Conference, Barcelona, Spain. Radiother Oncol 103(S1):S126-S127, 5/2012. | |
| 18. | Lessard F, Therriault-Proulx F, Després P, Archambault L, Beddar S, Beaulieu L. Low energy photon dosimetry using plastic scintillation detectors. ESTRO 31 Conference, Barcelona, Spain. Radiother Oncol 103(S1):S87-S88, 5/2012. | |
| 19. | Robertson D, MIrkovic D, Beddar AS. Quenching correction for volumetric scintillation dosimetry of proton beams. ESTRO 31 Conference, Barcelona, Spain. Radiother Oncol 103(S1):S310-S311, 5/2012. | |
| 20. | Therriault-Proulx F, Beddar S, Archambault L, Beaulieu L. A new optically encoded single-fiber plastic scintillation detector for multi-point radiation dosimetry. COMP Proceedings of the 58th Annual Scientific Annual Meeting, Halifax, Canada:19, 7/2012. | |
| 21. | Therriault-Proulx F, Beaulieu L, Archambault L, Beddar S. A novel multi-point plastic scintillation detector for in vivo dosimetry and quality assurance in radiation therapy. AAPM 54th Annual Meeting, July 29 - August 2, 2012, Charlotte, North Carolina, Med. Phys. 39(6):3967, 7/2012. | |
| 22. | Robertson D, Mirkovic D, Beddar S. A quenching correction method for volumetric scintillation dosimetry of proton beams. AAPM 54th Annual Meeting, July 29 - August 2, 2012, Charlotte, North Carolina, Med. Phys. 39(6):3886, 7/2012. | |
| 23. | Wootton L, Klein D, Bonde C, Adams E, Schmidt D, Beaulieu L, Beddar S. Characterization of a commercial photodiode based plastic scintillation detector prototype. AAPM 54th Annual Meeting, July 29 - August 2, 2012, Charlotte, North Carolina. Med. Phys. 39(6):3886, 7/2012. | |
| 24. | Therriault-Proulx F, Beaulieu L, Archambault L, Beddar S. On the importance of fluorescence within the stem effect of scintillation detectors. AAPM 54th Annual Meeting, July 29 - August 2, 2012, Charlotte, North Carolina, Med. Phys. 39(6):3967, 7/2012. | |
| 25. | Lessard F, Archambault L, Plamondon M, Despres P, Therriault-Proulx F, Beddar S, Beaulieu L. Plastic scintillation detector validation for kV dosimetry. COMP Proceedings of the 58th Annual Scientific Annual Meeting, Halifax, Canada:92, 7/2012. | |
| 26. | Ingram WS, Robertson D, Beddar S. The water equivalence of organic liquid scintillators for proton dosimetry. AAPM 54th Annual Meeting, July 29 - August 2, 2012, Charlotte, North Carolina, Med. Phys. 39(6):3729, 7/2012. | |
| 27. | Mackin D, Polf J, Peterson S, Beddar S. Three-stage compton camera image resolution losses due detector effects. AAPM 54th Annual Meeting, July 29 - August 2, 2012, Charlotte, North Carolina, Med. Phys. 39(6):3882, 7/2012. | |
| 28. | Mackin D, Polf J, Peterson S, Beddar S. Using the distance of closest approach to improve compton camera image quality. AAPM 54th Annual Meeting, July 29 - August 2, 2012, Charlotte, North Carolina, Med. Phys. 39(6):3670, 7/2012. | |
| 29. | Palmer M, Mok H, Ciura K, Georges R, Nguyen B, Crawford C, Beddar S, Zhu R, Crane C, Das P. Dose reduction to small bowel and other relevant structures in rectal carcinoma with proton therapy. ASTRO 2012 Annual Meeting, Oct. 28 - 31, 2012, Boston, Massachusetts, Int J Radia Oncol Biol Phys 84(3):S846, 11/2012. | |
| 30. | Hynstrom JR, Tzeng CD, Beddar S, Delclos ME, Crane CH, Krishnan S, Das P, Skibber JM, Rodriguez-Bigas MA. Intraoperative radiation therapy for locally advanced primary and recurrent colorectal cancer: ten-year institutional experience. ASTRO 2012 Annual Meeting, Oct. 28 - 31, 2012, Boston, Massachusetts, Int J Radia Oncol Biol Phys 84(3):S345, 11/2012. | |
| 31. | Wootton L, Beddar AS. Characterization of the temperature dependence of BCF scintillation detectors. 2nd ESTRO Forum, April 19-23, 2013, Geneva, Switzerland, 2013. | |
| 32. | Suh Y, Swanick SW, Beddar AS, Crane CH. Duodenal dose sparing with varying stomach volume during IG-IMRT treatment. ASTRO 2013 Annual Meeting, Sept. 22-25, Atlanta, Georgia, 2013. | |
| 33. | Kudchadker RJ, Wootton LS, Lee AK, Beddar AS. Localization methodology for water-equivalent plastic scintillation detectors using surrogate fiducials in CT. 2nd ESTRO Forum, April 19-23, 2013, Geneva, Switzerland, 2013. | |
| 34. | Archambault L, Beaulieu L, Klein d, Bourgouin A, Wootton L, Therriault-Proulx F, Beddar S. Performance of the first commercial miniature plastic scintillation detector. 2nd ESTRO Forum, April 19-23, 2013, Geneva Switzerland, 2013. | |
| 35. | Beddar S, Wootton LS, Kudchadker RJ, Lee AK. Preliminary results of an online patient in-vivo dosimetry protocol to monitor anterior rectal wall dose in real time. 2nd ESTRO Forum, April 19-23, 2013, Geneva, Switzerland, 2013. | |
Book Chapters | ||
| 1. | Cygler JE, Tanderup K, Beddar AS, Perez-Calatayud J. In Vivo Dosimetry in Brachytherapy. In: Comprehensive brachytherapy: Physical and Clinical Aspects. Ed(s) Venselaar J, Baltas D, Meigooni AS, Hoskin P. Taylor and Francis, 379-397, 2012. | |
| 2. | Beddar AS. Mobile Electron Beam Intraoperative Radiation Therapy. In: Quality and Safety in Radiotherapy. First Edition. Ed(s) T Pawlicki, P Dunscombe, AJ Mundt, P Scalliet. Taylor & Francis, 497-502, 2010. ISBN: 978-1-4398043-6-0. | |
| 3. | Beddar S and Briere TM. Plastic Scintillation Detectors. In: Clinical Dosimetry for Radiotherapy. Ed(s) Rogers DWO and Cygler JE. Medical Physics Publishing: Madison, WI, USA, Ch 34, pp 1059-1082, 2009. | |
| 4. | Crane CH, Beddar AS, and Evans DB. The Role of IORT in Pancreatic Cancer. In: Surgical Oncology Clinics. 12, 4. W.B. Saunders Company, 965-978, 2003. | |
Grant & Contract Support
| Title: | Patient in-vivo dosimetry measurements using the Radiadyne OARTrac System - Phase III |
| Funding Source: | Radiadyne |
| Role: | Principal Investigator |
| Duration: | 9/4/2012 - 2/28/2013 |
| Title: | Real-time in vivo rectal wall dosimetry for prostate radiotherapy using plastic scintillating detectors |
| Funding Source: | The University of Texas MD Anderson Cancer Center / Institutional Research Grant |
| Role: | Collaborator |
| Duration: | 9/1/2012 - 9/1/2014 |
| Title: | An in-vivo plastic scintillation detector for ultrasound-guided seed implantation during low-dose-rate prostate brachytherapy |
| Funding Source: | Odyssey Program and THE ESTATE OF C.G. JOHNSON, JR. |
| Role: | PI and Mentor |
| Duration: | 9/1/2012 - 8/30/2014 |
| Title: | Real-time verification of proton dose delivery. NCE |
| Funding Source: | NIH/NCI |
| Role: | Principal Investigator |
| Duration: | 6/30/2012 - 6/30/2013 |
| Title: | Performance evaluation of the Radiadyne OARTrac system - Phase II |
| Funding Source: | Radiadyne |
| Role: | Principal Investigator |
| Duration: | 9/1/2011 - 9/1/2012 |
| Title: | Performance evaluation of the Radiadyne OARTrac system - Phase I |
| Funding Source: | Radiadyne |
| Role: | Principal Investigator |
| Duration: | 6/1/2011 - 8/31/2011 |
| Title: | Water-Equivalent Plastic Scintillation Detectors for Small-Field Radiotherapy - SBIR Phase I |
| Funding Source: | NIH/NCI |
| Role: | Principal Investigator-MDACC |
| Duration: | 9/1/2010 - 8/31/2011 |
| Title: | Real-time in vivo dosimetry in radiation therapy using scintillation detectors. NCE |
| Funding Source: | NIH/NCI |
| Role: | Principal Investigator |
| Duration: | 6/1/2010 - 5/31/2011 |
| Title: | Optimizing Proton Radiation Therapy |
| Funding Source: | NIH/NCI |
| Role: | Co-Investigator |
| Principal Investigator: | Thomas DeLaney |
| Duration: | 9/25/2008 - 7/31/2013 |
| Title: | Real-time in vivo Dosimetry in Radiation Therapy using Scintillation Detectors |
| Funding Source: | NIH/NCI |
| Role: | Principal Investigator |
| Duration: | 7/1/2007 - 5/31/2010 |
| Title: | Scintillator detector system: real-time in vivo dosimetry in radiation therapy. |
| Funding Source: | The University of Texas MD Anderson Cancer Center Technology Review Committee |
| Role: | Principal Investigator |
| Duration: | 3/5/2007 - 11/4/2007 |
| Title: | Performance of the new design of the implantable dosimeter Detectors (DVS). |
| Funding Source: | Sicel Technologies |
| Role: | Co-Principal Investigator |
| Principal Investigator: | Briere |
| Duration: | 10/15/2006 - 4/15/2007 |
| Title: | Dose-image guided radiotherapy for prostate cancer |
| Funding Source: | NIH/NCI |
| Role: | Mentor and Project Leader |
| Principal Investigator: | Edward Jackson |
| Duration: | 8/4/2006 - 7/31/2011 |
| Title: | Plastic scintillator dosimeter array for IMRT and IMPT |
| Funding Source: | Odyssey Program and Houston Endowment, Inc. |
| Role: | PI and Mentor |
| Duration: | 2/1/2006 - 2/1/2009 |
| Title: | Un nouveau systéme dosimétrique a fibres optiques scintillantes pour application médicale. |
| Funding Source: | National Sciences and Engineering Research Council of Canada (NSERC) |
| Role: | Co-Investigator |
| Duration: | 4/1/2005 - 3/31/2008 |
| Title: | Clinical Evaluation of the Sicel Implantable Detectors |
| Funding Source: | Sicel Technologies |
| Role: | Principal Investigator |
| Duration: | 12/1/2003 - 12/30/2005 |
| Title: | Implantable Detectors |
| Funding Source: | Sicel Technologies |
| Role: | Principal Investigator |
| Duration: | 3/21/2003 - 9/30/2003 |
Last updated: 5/3/2013
- Global Navigation
- About Us
- Locations
- Calendar
- Careers
- Publications
- How You Can Help
- Contact Us
- Newsroom
- Site Index
- Patient and Cancer Information
- myMDAnderson
- Cancer Information
- Patient Information
- Care Centers & Clinics
- Children's Cancer Hospital
- Services & Amenities
- Education and Research
- Departments, Programs and Labs
- PeopleFinder
- Research at MD Anderson
- Education & Training
- Resources for Professionals
- For Employees
- Employee Alert Information
- Employee Resources
- Doing Business
- Vendors & Suppliers
- Partners & Affiliates
- Legal and Policy
- Legal Statements
- Site Policies
- Reporting Fraud, Waste & Abuse
© 2010 The University of Texas M. D. Anderson Cancer Center

